New Bern, NC Plumbing & HVAC Services
Trusted Heating, Cooling, and Plumbing Solutions for New Bern Homeowners
Since 1974, Jackson & Sons has been the trusted name for heating and air conditioning in New Bern. From fast AC repairs to full system replacements, our experienced technicians deliver high-quality solutions with a personal, family-oriented approach.
We are proud to expand our services to include full residential plumbing. Whether you are dealing with a leaking pipe, a clogged drain, or need a new water heater installed, you can now rely on the same team that New Bern homeowners trust for HVAC.
Our goal is simple: to provide fast, reliable service that keeps your home comfortable and functioning year-round.
If you are looking for reliable HVAC or plumbing solutions in Craven County, we are just a call (980) 223-0791 or click away.

Keep Cool All Summer with Expert AC Services
Our air conditioning services are designed to keep your home comfortable through New Bernās hot and humid summers. Whether your system needs a quick fix or a full replacement, we have the tools and training to get it done right.
AC Repair When You Need It Most
- Diagnose and fix warm air, short cycling, or poor airflow
- Address electrical or refrigerant issues causing system failure
- Service all major brands with fully stocked trucks for faster repairs
Energy-Efficient AC Installation
- Evaluate your home size, layout, and comfort needs
- Install energy-efficient central AC systems or heat pumps
- Properly size and balance airflow for long-term system performance
Stay Warm and Worry-Free with Reliable Heating Solutions
When temperatures drop, you need a heating system that works reliably. We provide repair, replacement, and maintenance services for furnaces and heat pumps to keep your home warm and energy-efficient through the winter.
Furnace and Heat Pump Repairs
- Troubleshoot uneven heating, pilot light issues, or strange noises
- Repair heat pumps, gas furnaces, and hybrid systems
- Restore consistent comfort and safe operation
New Heating System Installation
- Remove outdated or undersized systems
- Install high-efficiency furnaces and dual-fuel systems
- Help you select the right system for your home and energy goals
HVAC Maintenance
- Replace Filter / Clean If Permanent
- Disassemble Unit
- Clean Evaporator and Condenser Coils
- Remove All Leaves and Debris
- Tighten All Electrical Connections
- Measure Amp Draws on compressor, Motors and Heat Strips
- Inspect Outdoor Fan Blade
- Clean and Adjust Blower Wheel if Needed
- Clean and Inspect Flow of Condensate Drain
- Inspect and Test Defrost Cycle
- Inspect Crank Case Heater
- Test Capacitors
- Reassemble Unit, Replace Any Missing or Rusted Screws
- Wash Unit and Apply Protective Coating
- Monitor and Record Delta T
- Inspect Duct System
- Monitor Air Flow
- Inspect Thermostat and Reset to Customer Desire Settings
- Cycle System to Ensure Proper Operation
Restore Airflow and Efficiency with Ductwork Services
Professional Duct Repairs
Damaged or leaking ductwork can lead to hot and cold spots, reduced airflow, and increased energy bills. Our team identifies problem areas using pressure testing and thermal imaging, then seals, insulates, or repairs duct sections to restore performance and indoor comfort.
Complete Duct Replacement
If your ducts are undersized, poorly installed, or beyond repair, we can design and install a new duct system that supports your HVAC equipment and improves air distribution throughout your home. We follow best practices for airflow balance and energy efficiency.
Plumbing Solutions That Get the Job Done Right in New Bern
We bring the same level of professionalism and care to our plumbing services as we do to HVAC. Whether it is a small leak or a major backup, our licensed plumbers are ready with fast, effective solutions for your New Bern home.
Fix Whatās Leaking with Dependable Plumbing Repairs
Leaky fixtures and damaged pipes can waste water and drive up your utility bill. We handle a wide range of plumbing issues with solutions that last.
- Fix leaking faucets, running toilets, and burst pipes
- Repair water pressure issues and faulty shut-off valves
- Provide fast diagnosis and long-lasting repair options
Clear the Way with Drain and Sewer Services
Clogged drains can lead to water damage, foul odors, and recurring plumbing problems. Our team uses professional-grade equipment to clear and restore flow.
- Clear clogs in kitchen sinks, bathtubs, showers, and toilets
- Remove buildup, grease, and debris from interior and exterior lines
- Prevent backups and recurring drain problems with professional tools
Count on Us for Hot Water Help
A dependable water heater is essential to your daily routine. When hot water runs out or your system shows signs of trouble, we are here to restore comfort.
- Diagnose no hot water, rust-colored water, or strange noises
- Repair or replace tank and tankless water heater systems
- Install high-efficiency models sized for your householdās usage
Fixture Replacements For Your Home
Outdated or corroded fixtures not only affect function, they can impact your water usage and homeās appearance. We help modernize and improve performance.
- Upgrade faucets, toilets, and showerheads for better performance
- Replace corroded or leaking plumbing connections
- Improve water efficiency and refresh your homeās appearance
Emergency Plumbing When You Need It Now
Plumbing emergencies canāt wait. Whether your home is flooding from a burst pipe or your sewer line has backed up, our team responds quickly to protect your home and restore service during our business hours.
- Immediate help for pipe bursts, severe leaks, or flooding
- Fast response to water heater failure or sewer backups
- Restore safety and prevent further water damage
Why New Bern Homeowners Choose Jackson & Sons
Jackson & Sons has been a trusted name in heating and cooling for New Bern homeowners since 1974. For over 50 years, weāve delivered expert HVAC repairs, replacements, and maintenance with the kind of care only a family-oriented company can offer.Ā
Now, weāre proud to bring that same level of professionalism and reliability to your plumbing system. While plumbing is a newer service for us, itās backed by the same values, training, and customer-first mindset that have made our HVAC team one of the highest rated in Eastern North Carolina.
When you choose Jackson & Sons, you can expect:
- Licensed, background-checked HVAC and plumbing professionals
- Fast, responsive service with same-day availability whenever possible
- Honest pricing and clear communication
- Thousands of 5-star reviews from satisfied customers
- A team that truly cares about the comfort and safety of your home
When you need us, weāll be there ā with reliable service you can count on.
Call (980) 223-0791 or contact us online to schedule HVAC or plumbing service in New Bern today. We look forward to earning your trust and making your home more comfortable.
Recent Jobs and Reviews in New Bern, NC
New Bern, NC at a glance
Jackson & Sons has completed 25 jobs in New Bern, NC in July 2024.
The most recent job was on July 18, 2024.
Jackson & Sons completed its first job in New Bern, NC in September 2016.
Our Local Reviews by City
- Albertson, NC (17)
- Ayden, NC (26)
- Bailey, NC (9)
- Benson, NC (14)
- Beulaville, NC (21)
- Black Creek, NC (3)
- Brogden, NC (163)
- Calypso, NC (5)
- Chinquapin, NC (3)
- Clayton, NC (170)
- Clinton, NC (80)
- Cove City, NC (4)
- Deep Run, NC (32)
- Dover, NC (2)
- Dudley, NC (121)
- Dunn, NC (16)
- Elm City, NC (5)
- Erwin, NC (1)
- Faison, NC (40)
- Farmville, NC (30)
- Four Oaks, NC (69)
- Fremont, NC (148)
- Garner, NC (15)
- Goldsboro, NC (4285)
- Grantham, NC (2)
- Greenville, NC (175)
- Grifton, NC (14)
- Hookerton, NC (14)
- Jason, NC (1)
- Kenansville, NC (18)
- Kenly, NC (79)
- Kinston, NC (235)
- La Grange, NC (316)
- Lillington, NC (4)
- Lucama, NC (4)
- Magnolia, NC (4)
- Mar-Mac, NC (22)
- Micro, NC (2)
- Middlesex, NC (2)
- Mount Olive, NC (195)
- Nashville, NC (15)
- New Bern, NC (206)
- Newton Grove, NC (40)
- North Clinton, NC (1)
- Pikeville, NC (414)
- Pine Level, NC (5)
- Pink Hill, NC (27)
- Plain View, NC (1)
- Princeton, NC (156)
- Richlands, NC (3)
- Rocky Mount, NC (63)
- Rose Hill, NC (2)
- Roseboro, NC (6)
- Selma, NC (90)
- Seven Springs, NC (103)
- Sims, NC (2)
- Smithfield, NC (149)
- Snow Hill, NC (127)
- Stantonsburg, NC (30)
- Tarboro, NC (8)
- Teachey, NC (1)
- Turkey, NC (6)
- Vanceboro, NC (10)
- Wallace, NC (5)
- Walnut Creek, NC (45)
- Walstonburg, NC (9)
- Warsaw, NC (33)
- Wendell, NC (10)
- Willow Spring, NC (2)
- Wilson, NC (50)
- Wilson Mills, NC (1)
- Winterville, NC (94)
- Zebulon, NC (3)
Job Locations and Reviews
Customer not home. Emailed proposal
Tech found liquid pressure was over 415PSIG (R22) on 31 year old American Standard split system. Tech found completely obstructed condenser coils from debris build up. Tech found a leak in the evaporator coil (see attached video), likely caused by excessive pressure. Evaporator coil is no longer available from manufacturer. Advised customer to replace system, on account of age, condition, and repair costs.
Tech found liquid pressure was over 415PSIG (R22) on 31 year old American Standard split system. Tech found completely obstructed condenser coils from debris build up. Tech found a leak in the evaporator coil (see attached video), likely caused by excessive pressure. Evaporator coil is no longer available from manufacturer. Advised customer to replace system, on account of age, condition, and repair costs.
Tech found liquid pressure was over 415PSIG (R22) on 31 year old American Standard split system. Tech found completely obstructed condenser coils from debris build up. Tech found a leak in the evaporator coil (see attached video), likely caused by excessive pressure. Evaporator coil is no longer available from manufacturer. Advised customer to replace system, on account of age, condition, and repair costs.
Tech found liquid pressure was over 415PSIG (R22) on 31 year old American Standard split system. Tech found completely obstructed condenser coils from debris build up. Tech found a leak in the evaporator coil (see attached video), likely caused by excessive pressure. Evaporator coil is no longer available from manufacturer. Advised customer to replace system, on account of age, condition, and repair costs.
Have options. Has to speak with wife
Metal piece wedge in garbage disposal change out fill valve do to restricts in water flow
Upon arrival tech was shown where insulation on supply duct had fallen down again. Tech removed bottom section of insulation and resealed duct work. Installed new insulation and stapled and taped into place. Ensured all areas were well insulated. Tech vacuumed water from aux drain pan from where condensation had caused it to partially fill up.
Upon arrival, tech found condenser fan motor not running and 240V power from disconnect to contactor was inconsistent and unstable. Tech found faulty 30A breaker in disconnect box and replaced for testing purposes. With breaker replaced and a capacitor within required microfarad range, fan motor pulled 05 amps and would not rotate. Manually pushing fan blades would run the fan but would over-amp and fail shortly after. After giving the customer an estimate to repair, they requested a quote to replace the system. Tech examined general condition of condenser and air handler and found no issues in the air handler. Tech found exposed thermostat wires on the ground at the condenser unit and burnt contacts on the contactor. Left power off to condenser and power on to the air handler for air circulation.
Upon arrival, tech found condenser fan motor not running and 240V power from disconnect to contactor was inconsistent and unstable. Tech found faulty 30A breaker in disconnect box and replaced for testing purposes. With breaker replaced and a capacitor within required microfarad range, fan motor pulled 05 amps and would not rotate. Manually pushing fan blades would run the fan but would over-amp and fail shortly after. After giving the customer an estimate to repair, they requested a quote to replace the system. Tech examined general condition of condenser and air handler and found no issues in the air handler. Tech found exposed thermostat wires on the ground at the condenser unit and burnt contacts on the contactor. Left power off to condenser and power on to the air handler for air circulation.
Upon arrival, tech found condenser fan motor not running and 240V power from disconnect to contactor was inconsistent and unstable. Tech found faulty 30A breaker in disconnect box and replaced for testing purposes. With breaker replaced and a capacitor within required microfarad range, fan motor pulled 05 amps and would not rotate. Manually pushing fan blades would run the fan but would over-amp and fail shortly after. After giving the customer an estimate to repair, they requested a quote to replace the system. Tech examined general condition of condenser and air handler and found no issues in the air handler. Tech found exposed thermostat wires on the ground at the condenser unit and burnt contacts on the contactor. Left power off to condenser and power on to the air handler for air circulation.
Upon arrival, tech found condenser fan motor not running and 240V power from disconnect to contactor was inconsistent and unstable. Tech found faulty 30A breaker in disconnect box and replaced for testing purposes. With breaker replaced and a capacitor within required microfarad range, fan motor pulled 05 amps and would not rotate. Manually pushing fan blades would run the fan but would over-amp and fail shortly after. After giving the customer an estimate to repair, they requested a quote to replace the system. Tech examined general condition of condenser and air handler and found no issues in the air handler. Tech found exposed thermostat wires on the ground at the condenser unit and burnt contacts on the contactor. Left power off to condenser and power on to the air handler for air circulation.
Bad od fan motor and breaker. Customer is selling home. Wants to have system repaired but does not have the funds at this time. Will call when she is ready for repair
Upon arrival tech was informed one side of huse was hot and one side would be cold. Tech inspected duct work and found a couple of branch lines were over 25 feet long. Initial truck line was 14ā and reduced down to 12ā. Also found none of the branch lines had dampers at collar to damper down air flow for the vents getting a lot of air. There are 12-6ā lines and 1-8ā line. Homeowner wants quote to install dampers and adjust air flow. System is a 2003 with R22 Freon, customer wants to get quote for new system and duct repairs as well. Estimate for service to install dampers was emailed to customer.
Customer stated system was not cooling, tech was unable to find any challenges at todayās visit system pressures are running at spec and delta t is a little low at 16. Tech suspects may be and issue with ductwork tech was unable to fit past supply line may have to send a smaller tech to inspect. Customer is going to keep an eye on it over the next couple days and call if keeps happening.
Invested in new system
Upon arrival tech found both zones not responding, tech found control board not sending signal to open or close. Tech reprogrammed t stat accordingly to control board manual both zones are now open and closing properly at this time.
esa ON 1 SYSTEM---PREPAID Upon arrival tech found system not able to keep up, tech found evap coil very dirty tech cleaned to get accurate pressures. Tech found system has non condensables unable to meter refrigerant. Due to price of r22 repair tech recommended replacing system, field supervisor coming out to give all options.
Tech performed ESA on 1 system. HP Split- tech found no challenges at todayās visit system is operating properly at this time.
Invested in shares for upstairs and down
Has to talk with wife
Staff reported another company was out here an hour ago and reported broken blower wheel. Tech confirmed broken blower wheel on R22 Goodman split system. System is 18 years old. To get system running would require 3/4 HP blower motor and blower wheel. R22 standing pressure is 130 psi with system not running. Unable to run test system to assess R22 charge. Due to age and cost of repairs, tech recommends getting quote on system replacement. Put repair quote on ServiceTitan for field supervisor. May require additional repairs after getting a working blower. Recommend system replacement. Passed mandatory to Colby. Collected for service call.
Customer pointed to substance on bathroom ceiling and also reported system not keeping up. Tech found blower speed on medium (red) for 2nd stage and low (blue) for first stage. Also found Ecobee running schedule "until next activity". Tech also found the supply for the front central supply boot disconnected. Tech reconnected flex duct, secured with two panduit straps and taped up nylon barrier with sure tape. Changed Ecobee settings to "until you change it". Got pics of threshold menu.Changed blower speed to medium and medium high. Recorded amp draws and pressures. Found no further issues. InstLl warranty.
Upon arrival tech was informed blower was not running. Inspected system and found line voltage wire at wire nuts were melted at one leg. Tech repaired connection with split bolts. Turned system on and found blower still not coming on due to blow relay. Installed relay to bypass board and get system running. Homeowner wants to go ahead and order new board. Quoted for replace blower fan relay. System is back operational at this time.
25TPA736A003/FT4BNXC48L00