Zebulon NC Heating & Air Conditioning Services

Jackson and Son specializes in professional, 100% guaranteed residential and commercial heating and air conditioning installation, maintenance tune-ups and repair services.

Read what your Zebulon, NC neighbors say about our quality services, then call us at 919-734-9611 to schedule an appointment.

Recent Jobs and Reviews in Zebulon, NC

Rated 5.0 out of 5 stars based on 3 customer reviews

Our Local Reviews by City

Job Locations and Reviews

Kenny C.
Kenny C. Checked in
Performed ESA, tech found no issues at todays visit. Homeowner extended ESA. Discussed plasma air purifier.
Zebulon, NC 27597
Kyle W.
Kyle W. Checked in
Found dual run capacitor failed. Replaced under warranty pricing. System up and cooling. Customer also pointed out discoloration on hallway ceiling. Did not find any signs of condensation challenges from air handler. Verified proper drainage. Will need to keep a check on issue and double check during 1st maintenance. Invested in ESA (2) systems. Schedule 1st visit.
Zebulon, NC 27597
Aidan T.
Aidan T. Checked in
Tech inspected and diagnosed HP units# 5, 6, 7, 10, 11, and 13. -HP #5 Faulty contactor not allowing power through. Replaced and system ran normally. -HP #6 System running normally. Advised installation of air filter. Pressures look good. Tech suspects unit 5 being down has forced unit 6 to carry both loads, decreasing efficiency. -HP #7 System running normally. Inspected electrical components and refrigerant pressures and found no issues. -HP #10 Not running efficiently. R22 compressor is likely losing compression potential. Pressures and amp draw look good. Management wants to replace this system. -HP #11 Compressor is shorting out. Runs for 3-5 seconds and smoke starts to appear at terminal plug-in before tripping the breaker. Capacitor read full capacitance. Management wants to replace this system. -HP #13 Condenser fan motor is seized. Receiving 230V power and capacitor is good. Overheats in 10-15 seconds before failing completely. Management wants to replace this system. Se
Zebulon, NC 27597
Joshua C.
Joshua C. Checked in
Performed CMA Full Service on 4 Rooftop Gas Pack Units, 2 make up air units, 2 condensers, and 1 DOAS system. Technician also ensured exhaust fans were operating during the time of maintenance. Challenge - GP 2 - technician observed circuit 1 not operating. There was a call for Y1 and Y2, however only circuit 2 was operating. Previous notes recommended a leak search of circuit 1 given that the system was likely low on refrigerant. Leak search performed and a leak was found in the evaporator coil of circuit 1 (video and picture provided). Office notified and a quote will be built with a goal to repair the leak. Challenge - GP 4 - upon arrival to the system the tech discovered that circuit 1 was not operating, similar to GP 2. Technician inspected system and found compressor to be reading GOOD, no challenges in terms of electrical. Tech then leak searched the evaporator coil and found a couple of leaks on the bottom portion of the coil (video and pictures provided). Coil is heavily rus
Zebulon, NC 27597
Spencer C.
Spencer C. Checked in
Customer stated power outage and system was not cooling after. Customer stated system has been cooling since 8 last night and has not had an issue maintaining temperature. Tech offered to inspect system for system operational fee but stated it was likely due to power outage. Customer declined system operational and wants to see how system does. Tech instructed customer to call back if system is unable to keep up.
Zebulon, NC 27597
Landen  H.
Landen H. Checked in
Tech washed and serviced unit and found condensate line to be clogged up and not allowing water to drain tech cleared line unit is draining properly at this time tech found no other challenges at this time. Unit ismup and cooling with a delta t of 23
Zebulon, NC 27597
David  S.
David S. Checked in
-Complete approved repairs as follows: -Replace 7.5 mfd blower motor capacitor on AHU-9. -Replace 5 mfd blower motor capacitor on AHU-15. -Replace 7.5 mfd outdoor fan motor capacitor on HP-5. -Replace 5 mfd outdoor fan motor capacitor on HP-8. -Replace 7.5 mfd outdoor fan motor capacitor on HP-16. Was improperly estimated as 5 mfd. -Replace 35/5 mfd dual run capacitor on HP-6. -Replace blower motor belt on Make Up Air Unit. -Approval to relocate thermostat on AHU-16. After discussing with installation field supervisor, deciding that adjustment on dampers to appropriate air flow at supply locations would be a better path for correcting temperature issues with various locations serviced by system. Did not relocate thermostat. Closed off damper to main hall bathroom to reduce supply air at that location.
Zebulon, NC 27597
David  S.
David S. Checked in
-Customer recently had a different company perform a service call on downstairs split system due to it not performing to his liking. That company informed him that refrigerant levels/pressures were low and that system needed R22 refrigerant added but they do not work with R22. -Customer is aware that low refrigerant levels are an indicator of a leak in system. Is aware that topping off is at best a temporary repair and that Jackson and Sons will not be responsible for length of time this charge may aid system operation. -Informed customer that system should be thoroughly inspected for any additional problems, and recommended maintenance options moving forward. -Customer wishes to proceed with top off only to system. R22 to be recharged to levels per pressure curves as shown on unit documentation. System currently cooling with temperature difference of 16 degrees.
Zebulon, NC 27597
Luis R.
Luis R. Checked in
Tech pumped out water out of the auxiliary drain pan. Airhandler #2 is unleveled. Airhandler was leveled and cleared the drain line. Drain pan is corroded. Repairs for today are covered under install warranty.
Zebulon, NC 27597
David  S.
David S. Checked in
-Performed CMA Filter Change at 4 back of house locations, 1 DOAS System, and rooftop gas packs per maintenance agreement.
Zebulon, NC 27597
Anthony  B.
Anthony B. Checked in
X
Zebulon, NC 27597
David  S.
David S. Checked in
-Performed CMA Full Service on 16 Split System Heat Pumps. Verified operation of oven hood exhaust fan and make up air. Multiple repairs or recommendations for replacement of systems were made at last service in October 2023. Updated estimates provided. -System 2: Old style thermostat in place in hallway but no longer in use. -System 5: Outdoor fan motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $217.59. -System 6: Outdoor fan motor capacitor & compressor capacitor tested weak and were recommended for replacement at last service. Provided updated estimate $322.61. -System 8: Outdoor fan motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $213.00 -System 9: Air handler blower motor capacitor tested weak and was recommended for replacement at last service. Provided updated estimate $217.59. -System 10: Air handler blower motor capacitor tested weak and was recommended f
Zebulon, NC 27597
Spencer C.
Spencer C. Checked in
Tech replaced and tested heat strip contactor and found heat strips working properly. Heat strips set off fire alarm and tech explained this was due to dust buildup on the heating elements from heat strips not running and assured no cause for concern.
Zebulon, NC 27597
Matt C.
Matt C. Checked in
Tech washed and serviced unit
Zebulon, NC 27597
Open T.
Open T. Checked in
Tech found no difficulties at this time. Homeowner extended Psa. Tech recommended plasma air.
Zebulon, NC 27597
Spencer C.
Spencer C. Checked in
Tech found thermostat constantly restarting and throwing insufficient voltage error. Heat strip contactor was shorted causing a voltage drop. Tech was told by Jeff to email estimate in order to get approval. Tech also found thermostat set to emergency heat. Tech removed the common wire from the limit switch connected to the contactor to allow system to run temporarily.
Zebulon, NC 27597
Review
Prompt, thorough,clean. Takes time to answer our questions, let us know how to prioritize future issues for planning purposes. Always polite, never tromp debris through the house. We have been happy customers for many years and plan to remain so.
EVANS - Zebulon, NC 27597
Ricardo  T.
Ricardo T. Checked in
Tech performed ESA wanded coils no leaks at this time. Tech found dark pitted contactor tech suggested replacing sent estimate. Dropped off 20x30x1 filter.
Zebulon, NC 27597
Chris M.
Chris M. Checked in
Performed CMA inspection on 4 rooftop gas package systems, 2 make up air systems, and 1 DOAS system. Verified operation of exhaust fans. -RTU-2: During test cycle, compressor for circuit 1 does not operate. Unit transfers to compressor for circuit 2 at both stages of cooling test. Circuit 1 void of refrigerant. Recommend high level leak search. Provided estimate $385.63. -RTU-3: Gas heat cycled and immediately went off. Cleaned flame sensor and verified operation of heat. -Systems operating correctly at this time. Leak search needs to be performed on Gas Pack 2 circuit 1 (upon approval). Changed air filters at back of house location and left one case per agreement.
Zebulon, NC 27597
Chris M.
Chris M. Checked in
-Performed CMA inspection on 7 split systems. -Split System 1: System recommended for replacement at previous service. System ~18 yr old. Uses R22 refrigerant. Compressor megged as bad with windings shorting. Observed pitting and signs of heat damage on compressor contactor. Recommend replacing. Provided estimate $252.55. Outdoor fan motor capacitor tested as weak. Provided estimate for capacitor at last visit. New estimate price $198.14. -Split System 2: Observed pitting on compressor contactor. Recommend replacing. Provided estimate $252.55. Replace battery warning on thermostat. Estimate provided at last visit. Provided updated estimate $29.40. Condenser ~18 yr old, AH~3 yr old. No heat strips installed in system. Uses R22 refrigerant. Due to age and type of condenser, customer should consider replacement of condenser. -Split System 3: System recommended for replacement at previous service. System ~18 yr old. Uses R22 refrigerant. Compressor megged as bad and compressor shorted
Zebulon, NC 27597
Jesse J.
Jesse J. Checked in
Tech preformed CMA FILTER CHANGE on 4 Gas Pack systems, 1 DOAS system, 1 MPU system, and 1 Air Makeup unit. Tech replaced all filters and washed and cleaned all washable filters.Tech has attached Filter Change reports to invoice along with pictures.
Zebulon, NC 27597
Norman  A.
Norman A. Checked in
-Performed CMA inspection on 16 split systems. Verified operation of oven hood exhaust fan and make up air. -System 2: Old style thermostat in place. Provided estimate for replacement if requested $652.31. -System 5: Outdoor fan motor capacitor tested weak. Provided estimate for replacement of capacitor $202.56. -System 6: Outdoor fan motor capacitor & compressor capacitor tested weak. Recommend replacement of dual run capacitor. Provided estimate $322.61. -System 8: Outdoor fan motor capacitor tested weak. Provided estimate for replacement of capacitor $198.14. Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $206.68. -System 9: Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $202.56. -System 10: Air handler blower motor capacitor tested weak. Provided estimate for replacement of capacitor $198.14. Compressor megged bad. Windings shorting and compressor is due for failure. System is R22,
Zebulon, NC 27597
Logan P.
Logan P. Checked in
Tech washed and serviced unit and found no challenges at this time. Customer extended esa via check 265.81 check number 5971 until is running and cooling with a delta t of 20 return temp 77 and a supply temp of 57. Have next tech in the area drop off 2 14x20x1 filters.
Zebulon, NC 27597
Logan P.
Logan P. Checked in
Tech washed and serviced unit at this time and found no challenges at this time. Tech recommended adding plasma air customer is very interested but would like to wait until next visit. Unit is running and cooling with a delta t of 20, return temp 72 and a supply of 52.
Zebulon, NC 27597
Review
There is never a good time for the heat pump to break but Jackson and Sons always is right on it, usually seeing us the same day and gets us back up and running quickly and professionally. We are long term customers and plan to remain so.
EVANS - Zebulon, NC 27597
Review
Great customer service
Heather - Zebulon, NC 27597

Dependable Service Throughout Eastern NC

When you need heating or air conditioning repairs, maintenance or system replacements, you need a company you can count on for dependability and quality service. Contact us at Jackson & Sons at 919-734-9611. Our professional team of technicians look forward to providing energy efficient and cost effective solutions to keep your home or business comfortable at all times.

Contact Us

Why Jackson & Sons

Licensed, Bonded & Insured
Energy Efficient Experts
Same Day Repairs
5 Star Service
Dependable Warranties
Commercial & Residential Services
img-badge-bbb img-badge-epa img-badge-nate
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Contact and Service Location...
You and Your Service Location
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon
Back Next