Se Habla EspaƱol Our Services Call Now Request Service

New Bern, NC Plumbing & HVAC Services

Trusted Heating, Cooling, and Plumbing Solutions for New Bern Homeowners

Since 1974, Jackson & Sons has been the trusted name for heating and air conditioning in New Bern. From fast AC repairs to full system replacements, our experienced technicians deliver high-quality solutions with a personal, family-oriented approach.

We are proud to expand our services to include full residential plumbing. Whether you are dealing with a leaking pipe, a clogged drain, or need a new water heater installed, you can now rely on the same team that New Bern homeowners trust for HVAC.

Our goal is simple: to provide fast, reliable service that keeps your home comfortable and functioning year-round.

If you are looking for reliable HVAC or plumbing solutions in Craven County, we are just a call (980) 223-0791 or click away.

New Bern Nc

Keep Cool All Summer with Expert AC Services

Our air conditioning services are designed to keep your home comfortable through New Bern’s hot and humid summers. Whether your system needs a quick fix or a full replacement, we have the tools and training to get it done right.

AC Repair When You Need It Most

Energy-Efficient AC Installation

Stay Warm and Worry-Free with Reliable Heating Solutions

When temperatures drop, you need a heating system that works reliably. We provide repair, replacement, and maintenance services for furnaces and heat pumps to keep your home warm and energy-efficient through the winter.

Furnace and Heat Pump Repairs

New Heating System Installation

HVAC Maintenance

Restore Airflow and Efficiency with Ductwork Services

Professional Duct Repairs
Damaged or leaking ductwork can lead to hot and cold spots, reduced airflow, and increased energy bills. Our team identifies problem areas using pressure testing and thermal imaging, then seals, insulates, or repairs duct sections to restore performance and indoor comfort.

Complete Duct Replacement
If your ducts are undersized, poorly installed, or beyond repair, we can design and install a new duct system that supports your HVAC equipment and improves air distribution throughout your home. We follow best practices for airflow balance and energy efficiency.

Plumbing Solutions That Get the Job Done Right in New Bern

We bring the same level of professionalism and care to our plumbing services as we do to HVAC. Whether it is a small leak or a major backup, our licensed plumbers are ready with fast, effective solutions for your New Bern home.

Fix What’s Leaking with Dependable Plumbing Repairs

Leaky fixtures and damaged pipes can waste water and drive up your utility bill. We handle a wide range of plumbing issues with solutions that last.

Clear the Way with Drain and Sewer Services

Clogged drains can lead to water damage, foul odors, and recurring plumbing problems. Our team uses professional-grade equipment to clear and restore flow.

Count on Us for Hot Water Help

A dependable water heater is essential to your daily routine. When hot water runs out or your system shows signs of trouble, we are here to restore comfort.

Fixture Replacements For Your Home

Outdated or corroded fixtures not only affect function, they can impact your water usage and home’s appearance. We help modernize and improve performance.

Emergency Plumbing When You Need It Now

Plumbing emergencies can’t wait. Whether your home is flooding from a burst pipe or your sewer line has backed up, our team responds quickly to protect your home and restore service during our business hours.

Why New Bern Homeowners Choose Jackson & Sons

Jackson & Sons has been a trusted name in heating and cooling for New Bern homeowners since 1974. For over 50 years, we’ve delivered expert HVAC repairs, replacements, and maintenance with the kind of care only a family-oriented company can offer.Ā 

Now, we’re proud to bring that same level of professionalism and reliability to your plumbing system. While plumbing is a newer service for us, it’s backed by the same values, training, and customer-first mindset that have made our HVAC team one of the highest rated in Eastern North Carolina.

When you choose Jackson & Sons, you can expect:

When you need us, we’ll be there — with reliable service you can count on.

Call (980) 223-0791 or contact us online to schedule HVAC or plumbing service in New Bern today. We look forward to earning your trust and making your home more comfortable.

Recent Jobs and Reviews in New Bern, NC

Rated 4.9 out of 5 stars based on 206 customer reviews

Customers say: The reviews exhibit a positive overall sentiment, with a significant number of reviews expressing satisfaction and praise for the services provided by Jackson and Sons. The positive reviews highlight aspects such as excellent service, polite and informative technicians, quality installations, and friendly and helpful office staff. The recurring themes in the positive reviews include professionalism, punctuality, and the ability to address customer concerns effectively. However, there are also a few negative reviews, which primarily focus on issues such as delayed response times, scheduling conflicts, and dissatisfaction with the quality of work. The negative reviews mention specific instances where customers experienced problems or were not completely satisfied with the services provided. Overall, the sentiment of the reviews is positive, with a slight inclination towards the positive side. The recurring themes in the positive reviews indicate that Jackson and Sons generally provides high-quality services and strives to meet customer expectations. However, it is important to note that the negative reviews should not be overlooked, and the company should continue to work towards improving its services and addressing any issues that may arise.

New Bern, NC at a glance

Jackson & Sons has completed 25 jobs in New Bern, NC in June 2024.

The most recent job was on June 17, 2024.

Jackson & Sons completed its first job in New Bern, NC in September 2016.

Job Locations and Reviews

Aidan T.
Aidan T. Checked in
Tech performed ESA, tech found no issues at todays visit, system is back on and operating properly at this time. Customer supplies their own filters. Customer renewed.
New Bern, NC 28560
Aidan T.
Aidan T. Checked in
Tech performed ESA, tech found no issues at todays visit, system is back on and operating properly at this time. Customer supplies their own filters. Customer renewed.
New Bern, NC 28560
Aidan T.
Aidan T. Checked in
Tech performed ESA, tech found no issues at todays visit, system is back on and operating properly at this time. Customer supplies their own filters. Customer renewed.
New Bern, NC 28560
Kyle W.
Kyle W. Checked in
FOUND SUPPLY PLENUM INSULATION IN POOR CONDITION/TAPE UNDONE CAUSING PLENUM TO SWEAT ONTO ATTIC FLOOR. DRAINED EXCESS WATER AND PUT BUCKETS UNDERNEATH FOR TIME BEING. REPAIR AND MAINTENANCE IS SCHEDULED FOR FRIDAY BETWEEN 1-3PM. DO NOT RE-SCHEDULE UNLESS EARLIER IN THE WEEK.
New Bern, NC 28562
Kyle W.
Kyle W. Checked in
FOUND 10 TON SYSTEM LOW ON CHARGE. LOCATED LEAK AT SUCTION LINE FITTING. BUILT ESTIMATE FOR REPAIR. WILL CALL IN IF APPROVED. SYSTEM REPLACEMENT RECOMMENDED DUE TO AGE/REPAIR COSTS.
New Bern, NC 28562
Percy M.
Percy M. Checked in
TECH PERFORMED CMA FULL SERVICE ON 3 SPLIT SYSTEMS. ALL SYSTEMS ARE COOLING PROPERLY AND HAVE A PROPER DELTA T. AIR HANDLERS #2 and #3 WERE DOUBLE FILTERED, MEANING THERE WAS FILTERS INSIDE AIR HNDLER AND FILTERS INSIDE OF LAY IN FILTER GRILL. TECH REPLACED FILTERS INSIDE FILTER GRILL AND TOOK FILTERS OUT OF AIR HANDLERS TO ESURE PROPER AIR CIRCULATION. TECH WASHED CABNETS OF ALL 3 OUTSIDE CONDENSERS. PERFORMED AND COMPLETED FIKTER CHANGE OF 6-20x20x1 FILTERS AND 1-12x24x1 FILTER. THERE ARE PICTURES AND A PERFORMANCE REPORT ATTACHED TO THIS INVOICE.
New Bern, NC 28560
Kyle W.
Kyle W. Checked in
FOUND SYSTEM FREEZING UP DUE TO LOW REFRIGERANT CHARGE. LOCATED LEAK WITHIN EVAPORATOR COIL. OFFICE RECORDS SHOW SYSTEM IS NOT UNDER ANY WARRANTIES, BUT CUSTOMER HAS DOCUMENTS STATING THEY ARE GOOD UNTIL DECEMBER. NEED TO CALL AND VERIFY WITH CUSTOMER BEFORE ORDERING COIL. INVESTED IN PSA (1) SYSTEM.
New Bern, NC 28562
Chris M.
Chris M. Checked in
Installing a gas line for tankless water heater for customer.
New Bern, NC 28562
Matt C.
Matt C. Checked in
.
New Bern, NC 28562
Matt C.
Matt C. Checked in
Tech performed esa on carrier split heat pump, found no challenges at todays visit Customer extended esa
New Bern, NC 28562
Kenny C.
Kenny C. Checked in
Tech performed ESA on 1 system. Tech serviced and cleaned system. Tech faced no challenges at todays visit and system is running properly at this time.
New Bern, NC 28560
Kyle W.
Kyle W. Checked in
FOUND AUXILIARY PAN FULL OF WATER DUE TO PRIMARY DRAIN CONNECTIONS BEING INSTALLED ON HIGH END OF PRIMARY DRAIN PAN, CAUSING WATER TO OVERFLOW. CUT AND MOVED PRIMARY DRAIN LINE AND FLOAT SWITCH OVER TO LEFT PORTS TO LOW SIDE OF PAN. SYSTEM IS NOW DRAINING PROPERLY. INSTALL WARRANTY.
New Bern, NC 28560
Kyle W.
Kyle W. Checked in
(MINI SPLIT SYSTEM) FOUND LOW ON CHARGE CAUSING SYSTEM TO FREEZE UP. LOCATED LEAK WITHIN AIR HANDLER FLARE FITTINGS. TIGHTENED FITTING AND CHARGED SYSTEM TO PROPER SPECS WITH NO FURTHER LEAKS PRESENT. SYSTEM UP AND COOLING. INVESTED IN PSA (2) SYSTEMS. CALL TO SCHEDULE 1ST VISIT AS SOON AS POSSIBLE. NOTICED SMALL AMOUNT OF WATER WITHIN AUXILIARY PAN OF MAIN SYSTEM. CUSTOMER STATED HE WILL TAKE CARE OF IT FOR NOW AND ADDRESS DURNG MAINTENANCE VISIT.
New Bern, NC 28562
Matt C.
Matt C. Checked in
Tech performed esa on carrier package unit, found no challenges at todays visit Customer wasn’t home during maintenance Left filters on porch
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found unit running in single stage and no power at Y2. Tech put thermostat in test mode and found still no power at y2. Tech tied y1 and y2 together at thermostat and still only found power at Y1. This indicates a broken brown wire. Tech connected y1 and y2 together at the board and found system now running second stage. Manager on site also requested we look at the other unit as well. Tech found compressor 2 contactor not pulling in due to LSD2 safety module breaking power to y. Tech bypassed switch for diagnostic purposes and found no issues with pressures or amp draw and recommends replacing the module. MOD02964
New Bern, NC 28562
Matthew L.
Matthew L. Checked in
Three handles tub valve on hot side was leaking need the seat replaced in the mix valve
New Bern, NC 28562
Spencer C.
Spencer C. Checked in
Tech found drain exit was too high, and coil is dirty causing water to drip straight down versus rolling down the coil. Tech recommends a maintenance plan to clean coil and clear drain. Tech explained that if cleaning the coil doesn’t work for a downflow coil, the coil will have to be replaced. Tech also verified suction pressure not causing a frozen coil. Unit did look slightly low based on subcooling with a TXV and tech quoted topping system off. Customer agreed to maintenance agreement and minor repair to lower drain exit point. Tech addressed evaporator coil today and documented water now rolling down the coil instead of falling straight down. Tech also documented water exiting the drain. Customer wants receipt mailed
New Bern, NC 28560
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at (980) 223-0791 .

By pressing Submit I agree to receive phone, email, or text messages from Jackson & Sons to the provided mobile number and also agree to the Jackson & Sons terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next