Se Habla EspaƱol Our Services Call Now Request Service

Smithfield, NC Plumbing & HVAC Services

Professional Heating, Cooling, and Plumbing Services for Smithfield Homes

For over 50 years, Jackson & Sons has provided trusted HVAC service to homeowners in Smithfield and throughout Johnston County. Whether your AC breaks down in the middle of summer or your furnace stops working on a chilly morning, we deliver fast, reliable help backed by decades of experience.

Now, we’re proud to offer licensed plumbing services with the same dependable care. From drain cleaning and water heater repairs to emergency leaks, our plumbing team is ready to keep your home running smoothly.

Need help now? Call (980) 223-0791 or contact us online to schedule HVAC or plumbing service in Smithfield.

Carolina Pottery Smithfield 3 2 1

Air Conditioning Services That Keep You Cool in Smithfield

Our technicians are trained to handle all types of cooling issues, whether you need a quick repair or a completely new system.

AC Repair

  • Diagnose issues like warm air, low airflow, or system failure
  • Fix electrical faults, frozen coils, or refrigerant problems
  • Fast, same-day service available whenever possible

AC Installation

  • Install energy-efficient central air or heat pump systems
  • Proper sizing and airflow balancing for optimal performance
  • Full walk-through and system training included

Heating Services to Keep You Comfortable

We help you stay warm with reliable service for furnaces and heat pumps throughout the colder months.

Heating Repair

  • Identify common problems like no heat, uneven temps, or system cycling
  • Service for all brands of furnaces and heat pumps

New Heating Installation

  • Replace aging or inefficient systems with modern, energy-saving options
  • Expert guidance to find the best solution for your home

Heating & Cooling Maintenance

  • Replace Filter / Clean If Permanent
  • Disassemble Unit
  • Clean Evaporator and Condenser Coils
  • Remove All Leaves and Debris
  • Tighten All Electrical Connections
  • Measure Amp Draws on Compressor, Motors and Heat Strips
  • Inspect Outdoor Fan Blade
  • Clean and Adjust Blower Wheel if Needed
  • Clean and Inspect Flow of Condensate Drain
  • Inspect and Test Defrost Cycle
  • Inspect Crank Case Heater
  • Test Capacitors
  • Reassemble Unit, Replace Any Missing or Rusted Screws
  • Wash Unit and Apply Protective Coating
  • Monitor and Record Delta T
  • Inspect Duct System
  • Monitor Air Flow
  • Inspect Thermostat and Reset to Customer Desire Settings
  • Cycle System to Ensure Proper Operation

Full-Service Furnace and Heat Pump Solutions in Smithfield, NC

When winter temperatures drop in Smithfield, your home deserves a heating system you can rely on. At Jackson & Sons, we provide complete furnace and heat pump services tailored to your home’s needs. Whether you’re upgrading an aging system, handling unexpected repairs, or preparing for the season with routine maintenance, our licensed technicians have you covered.

  • Install energy-efficient furnaces and heat pumps for consistent winter comfort
  • Repair issues like uneven heating, strange smells, or short cycling
  • Perform seasonal maintenance to keep your system running safely and efficiently
  • Provide expert sizing and system recommendations for new homes or replacements

Stay warm all season long with dependable heating solutions backed by over 50 years of local service.

Indoor Air Quality Products & Services

Clean, healthy indoor air is essential for year-round comfort in Smithfield. At Jackson & Sons, we offer professional indoor air quality services designed to help your family breathe easier. Whether you are battling humidity, allergies, or poor airflow, we can recommend the right solution for your home.

Our indoor air quality services include:

  • Installing whole-home air purifiers to remove dust, allergens, and airborne pollutants
  • Adding dehumidifiers to control excess moisture and prevent mold growth
  • Recommending and installing energy-recovery ventilators for fresh air circulation
  • Upgrading HVAC filters and optimizing air handler settings for cleaner airflow
  • Conducting air quality assessments to tailor solutions to your home’s needs

Let us help you create a safer, healthier indoor environment in your Smithfield home.

Ductwork Services That Improve Airflow and Comfort

Leaky or poorly designed ductwork can drive up energy bills and leave parts of your home too hot or too cold. At Jackson & Sons, we offer professional ductwork services for homeowners in Smithfield to help restore comfort, improve system performance, and lower utility costs.

  • Duct Repair
    • Seal and reinforce damaged or disconnected ducts
    • Improve airflow to every room in your home
  • Duct Replacement
    • Remove and replace undersized or failing ductwork
    • Install properly insulated, balanced systems for peak efficiency

Plumbing Services for Every Room in the House

Now serving Smithfield with full-service plumbing, Jackson & Sons brings the same trusted care and professionalism our HVAC customers have counted on for decades. Whether you’re dealing with a slow drain, a leaking pipe, or an unexpected plumbing emergency, our licensed plumbers are ready to respond quickly with reliable, long-lasting solutions.

We proudly serve homes throughout Smithfield and nearby Johnston County communities with expert plumbing repairs, installations, and maintenance for kitchens, bathrooms, laundry rooms, and beyond.

Reliable Plumbing Repairs

  • Repair leaking faucets, burst pipes, and running toilets
  • Fix water pressure issues and damaged valves
  • Quick diagnosis with honest recommendations

Drain and Sewer Services

  • Clear tough clogs in kitchens, bathrooms, and main lines
  • Use professional-grade equipment to remove buildup and debris
  • Prevent future blockages and restore normal flow

Water Heater Services

  • Repair tank and tankless water heaters
  • Resolve no hot water, pilot light issues, or leaking units
  • Install efficient models to match your household size and needs

Fixture Upgrades

  • Replace outdated faucets, toilets, and showerheads
  • Improve water flow, efficiency, and appearance

Emergency Plumbing Help

  • Respond to burst pipes, major leaks, and backups
  • Stop damage and restore service fast with same-day availability

Why Smithfield Homeowners Trust Jackson & Sons

We’ve served the Smithfield community for generations with reliable HVAC service built on family values, professional workmanship, and local pride. With the addition of our plumbing division, we’re making it even easier to get expert care for your entire home.

  • Trusted HVAC provider since 1974
  • Now offering licensed plumbing services in Smithfield, NC
  • Family-oriented and operated with a focus on quality and integrity
  • Same-day service availability whenever possible
  • Backed by thousands of 5-star reviewsĀ 

When You Need Us, We’ll Be There — For HVAC and Plumbing in Smithfield, NC

Whether you need furnace repair, AC replacement, or urgent help with a plumbing issue, Jackson & Sons is here with fast, reliable service in Smithfield and nearby communities.

Call (980) 223-0791 or contact us online to schedule your HVAC or plumbing service today. When you need us, we’ll be there — with the comfort and care your home deserves.

Recent Jobs and Reviews in Smithfield, NC

Rated 5.0 out of 5 stars based on 149 customer reviews

Customers say: The reviews exhibit a positive overall sentiment, with a significant number of reviews expressing satisfaction and praise for the services provided by Jackson and Sons. The positive reviews highlight aspects such as excellent service, polite and informative technicians, quality installations, and friendly and helpful office staff. The recurring themes in the positive reviews include professionalism, punctuality, and the ability to address customer concerns effectively. However, there are also a few negative reviews, which primarily focus on issues such as delayed response times, scheduling conflicts, and dissatisfaction with the quality of work. The negative reviews mention specific instances where customers experienced problems or were not completely satisfied with the services provided. Overall, the sentiment of the reviews is positive, with a slight inclination towards the positive side. The recurring themes in the positive reviews indicate that Jackson and Sons generally provides high-quality services and strives to meet customer expectations. However, it is important to note that the negative reviews should not be overlooked, and the company should continue to work towards improving its services and addressing any issues that may arise.

Smithfield, NC at a glance

Jackson & Sons has completed 25 jobs in Smithfield, NC in June 2024.

The most recent job was on June 18, 2024.

Jackson & Sons has completed 1 job in Smithfield, NC in the last 12 months. The first job there was in August 2016.

Job Locations and Reviews

Ricardo T.
Ricardo T. Checked in
Tech washed and serviced unit and found no challenges at this time. Tech recommended capacitor replacement. Customer agreed tech replaced capacitor with turbo 200.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech found pressures at 140/430 on the circuit that’s had issues. Previous tech found it pumping down. Tech found that both liquid line solenoids are ran off the same circuit, so if one was getting power, both were getting power. Tech bypassed reheat solenoid by putting constant power on the coil and found system pumping down. This indicates circuit 1 liquid line solenoid is getting stuck closed. When reheat solenoid is open, refrigerant goes through the reheat coil bypassing the liquid line solenoid valve. Some refrigerant also bypasses the condenser coil which explains the elevated pressures. Tech has bypassed the reheat solenoid to allow compressor to run without pumping down.
Smithfield, NC 27577
Romario T.
Romario T. Checked in
Found the mini split for the server room with a low delta T. Only 71 degree temperature air was coming out of the supply. System is 1 lb low on r410a refrigerant. Tech charged the system after approval and acquired a better delta T, supply temperature of 52 degrees. Mini split is back cooling. Leak search is recommended, potential leaks at the fittings.
Smithfield, NC 27577
Romario T.
Romario T. Checked in
Refrigerant repairs were just performed. Found the circuit on the right( package unit that supplies the offices) with a negative suction pressure and 308 head pressure. System was turned off and inspected the TXV and noticed one of the liquid line/discrarge solenoids opened with the power off. Tech cycled the power back on and acquired a pressures of 68/308 for 10 minutes and then the suction pressure went up to 108 suction and discharge pressure of 328. Compressor amp draws were high during the operation, rated for 15amps and was pulling 12.4. Compressor went into thermal overload and could not get it to cool down on time prior to the bank closing. We would need to come back to figure out the main cause of the compressor getting hot and having abnormal refrigerant pressures. Left circuit is cooling as it should. Tech did close the economizer, which is currently un functional/ disconnected to prevent bringing in more hot ambient air. Tech unplugged the compressor on the right side to p
Smithfield, NC 27577
Luis R.
Luis R. Checked in
Tech found on ahu-3 found sc15 mini fuse was blown tech replaced with customer supplied blower engaged once compressor and condenser fan motor’s engaged fuse blew again upon further inspection tech found middle condenser fan motor had electrical failer due to fan blade rubbing off into wire motor will need to be ordered and replaced. 1/2hp 1075 rpm system #15 tech found od fan running but not compressor tech found wire from capacitor to compressor burnt as well as 35mfd capacitor tech quoted out dual run and turbo capacitor customer approved turbo capacitor.once replaced system is operating properly at this time.
Smithfield, NC 27577
Jesse J.
Jesse J. Checked in
Tech preformed CMA FILTER CHANGE on 7 Gas Package Units, 3 Air Makeup Units, 3 Mini Split Systems, 2 PTAC Units, 12 Package Heat Pump Units, and 5 RTU Units. Tech has attached FILTER CHANGE REPORTS to invoice along with pictures.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Spencer C.
Spencer C. Checked in
Tech replaced TXV and repaired leak while flowing nitrogen. Tech pressure tested, pulled a vacuum and restarted system. Tech then found 1 condenser fan motor locked up causing high head pressure. Tech got approval and replaced motor. Tech found system with slightly elevated head pressure at 440 but this is likely due to dirty coils and lack of maintenance. Tech also insulated all rub spots to prevent other leaks.
Smithfield, NC 27577
Derek J.
Derek J. Checked in
Upon arrival tech was informed another company came and put 29lbs of R22 in system to get back cooling last week and is already not cooling again. Tech leak searched system and found leak at evaporator coil. System has 2- 5 ton furnaces and 2- 5 ton coils twinned to 1- 10 ton condenser. Field Supervisor was already on site for handoff.
Smithfield, NC 27577
Romario T.
Romario T. Checked in
Found the service disconnect off at the airhandler. Water was found on the condensate drain pan for the pump, tech vacuumed out the water and pumped water thru the condensate pump motor and assured proper draining, tested system #2 prior to departure and system did not present challenges. Condenser pump may have been bumped into and caused it to not be balanced. Findings were emailed to the customer. System #2 has been found off at the disconnect during the last 2 visits. Tech is unsure on who or why the reason behind it is.
Smithfield, NC 27577

Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at (980) 223-0791 .

By pressing Submit I agree to receive phone, email, or text messages from Jackson & Sons to the provided mobile number and also agree to the Jackson & Sons terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next