Smithfield, NC Plumbing & HVAC Services
Air Conditioning Services That Keep You Cool in Smithfield
Our technicians are trained to handle all types of cooling issues, whether you need a quick repair or a completely new system.
AC Repair
- Diagnose issues like warm air, low airflow, or system failure
- Fix electrical faults, frozen coils, or refrigerant problems
- Fast, same-day service available whenever possible
AC Installation
- Install energy-efficient central air or heat pump systems
- Proper sizing and airflow balancing for optimal performance
- Full walk-through and system training included
Heating Services to Keep You Comfortable
We help you stay warm with reliable service for furnaces and heat pumps throughout the colder months.
Heating Repair
- Identify common problems like no heat, uneven temps, or system cycling
- Service for all brands of furnaces and heat pumps
New Heating Installation
- Replace aging or inefficient systems with modern, energy-saving options
- Expert guidance to find the best solution for your home
Heating & Cooling Maintenance
- Replace Filter / Clean If Permanent
- Disassemble Unit
- Clean Evaporator and Condenser Coils
- Remove All Leaves and Debris
- Tighten All Electrical Connections
- Measure Amp Draws on Compressor, Motors and Heat Strips
- Inspect Outdoor Fan Blade
- Clean and Adjust Blower Wheel if Needed
- Clean and Inspect Flow of Condensate Drain
- Inspect and Test Defrost Cycle
- Inspect Crank Case Heater
- Test Capacitors
- Reassemble Unit, Replace Any Missing or Rusted Screws
- Wash Unit and Apply Protective Coating
- Monitor and Record Delta T
- Inspect Duct System
- Monitor Air Flow
- Inspect Thermostat and Reset to Customer Desire Settings
- Cycle System to Ensure Proper Operation
Full-Service Furnace and Heat Pump Solutions in Smithfield, NC
When winter temperatures drop in Smithfield, your home deserves a heating system you can rely on. At Jackson & Sons, we provide complete furnace and heat pump services tailored to your homeās needs. Whether youāre upgrading an aging system, handling unexpected repairs, or preparing for the season with routine maintenance, our licensed technicians have you covered.
- Install energy-efficient furnaces and heat pumps for consistent winter comfort
- Repair issues like uneven heating, strange smells, or short cycling
- Perform seasonal maintenance to keep your system running safely and efficiently
- Provide expert sizing and system recommendations for new homes or replacements
Stay warm all season long with dependable heating solutions backed by over 50 years of local service.
Indoor Air Quality Products & Services
Clean, healthy indoor air is essential for year-round comfort in Smithfield. At Jackson & Sons, we offer professional indoor air quality services designed to help your family breathe easier. Whether you are battling humidity, allergies, or poor airflow, we can recommend the right solution for your home.
Our indoor air quality services include:
- Installing whole-home air purifiers to remove dust, allergens, and airborne pollutants
- Adding dehumidifiers to control excess moisture and prevent mold growth
- Recommending and installing energy-recovery ventilators for fresh air circulation
- Upgrading HVAC filters and optimizing air handler settings for cleaner airflow
- Conducting air quality assessments to tailor solutions to your homeās needs
Let us help you create a safer, healthier indoor environment in your Smithfield home.
Ductwork Services That Improve Airflow and Comfort
Leaky or poorly designed ductwork can drive up energy bills and leave parts of your home too hot or too cold. At Jackson & Sons, we offer professional ductwork services for homeowners in Smithfield to help restore comfort, improve system performance, and lower utility costs.
- Duct Repair
- Seal and reinforce damaged or disconnected ducts
- Improve airflow to every room in your home
- Duct Replacement
- Remove and replace undersized or failing ductwork
- Install properly insulated, balanced systems for peak efficiency
Plumbing Services for Every Room in the House
Now serving Smithfield with full-service plumbing, Jackson & Sons brings the same trusted care and professionalism our HVAC customers have counted on for decades. Whether youāre dealing with a slow drain, a leaking pipe, or an unexpected plumbing emergency, our licensed plumbers are ready to respond quickly with reliable, long-lasting solutions.
We proudly serve homes throughout Smithfield and nearby Johnston County communities with expert plumbing repairs, installations, and maintenance for kitchens, bathrooms, laundry rooms, and beyond.
Reliable Plumbing Repairs
- Repair leaking faucets, burst pipes, and running toilets
- Fix water pressure issues and damaged valves
- Quick diagnosis with honest recommendations
Drain and Sewer Services
- Clear tough clogs in kitchens, bathrooms, and main lines
- Use professional-grade equipment to remove buildup and debris
- Prevent future blockages and restore normal flow
Water Heater Services
- Repair tank and tankless water heaters
- Resolve no hot water, pilot light issues, or leaking units
- Install efficient models to match your household size and needs
Fixture Upgrades
- Replace outdated faucets, toilets, and showerheads
- Improve water flow, efficiency, and appearance
Emergency Plumbing Help
- Respond to burst pipes, major leaks, and backups
- Stop damage and restore service fast with same-day availability
Why Smithfield Homeowners Trust Jackson & Sons
Weāve served the Smithfield community for generations with reliable HVAC service built on family values, professional workmanship, and local pride. With the addition of our plumbing division, weāre making it even easier to get expert care for your entire home.
- Trusted HVAC provider since 1974
- Now offering licensed plumbing services in Smithfield, NC
- Family-oriented and operated with a focus on quality and integrity
- Same-day service availability whenever possible
- Backed by thousands of 5-star reviewsĀ
When You Need Us, Weāll Be There ā For HVAC and Plumbing in Smithfield, NC
Whether you need furnace repair, AC replacement, or urgent help with a plumbing issue, Jackson & Sons is here with fast, reliable service in Smithfield and nearby communities.
Call (980) 223-0791 or contact us online to schedule your HVAC or plumbing service today. When you need us, weāll be there ā with the comfort and care your home deserves.
Jackson & Sons has completed 25 jobs in Smithfield, NC between June 2024 and July 2024. The most recent job was on July 10, 2024. Jackson & Sons has completed 1 job in Smithfield, NC in the last 12 months. The first job there was in August 2016.Recent Jobs and Reviews in Smithfield, NC
Smithfield, NC at a glance
Our Local Reviews by City
Job Locations and Reviews
-Arrived to find thermostat calling for cooling and not satisfied. Found outdoor fan motor turning slowly and compressor not operating.
-Found dual run capacitor heavily swollen.
-Made needed repairs.
GPHH33041A
Upon arrival tech was informed system #22 was blowing air but it was not cold. Tech inspected system and found 40/5 mfd dual run capacitor failed. Replaced with new capacitor and condenser started up. Pressures and temperatures were within range. System is back operational at this time.
Tech was getting superheat fluctuations between 4-8 within secs of operating. Tech spoke with office and was instructed to removed refrigerant and pull vacuum. Tech pulled vacuum down to 340 microns added 6lbs 6oz. Once started up pressures were within specs and superheat was 2.7 for this system itās within specs tech had a 17 degree delta t. Duct work looked intact. Good airflow in vents. Tech informed customer to monitor system for a few days.
Upon arrival customer stated 3 systems that cool the back area of office werenāt cooling. Tech informed customer that previous estimates need to be approved in order to get systems back up and cooling or a field supervisor will need to get in contact. Customer also stated the 2nd system on the side of building wasn't keeping up, tech found pressures extremely low. Customer just wants a quote on replacing that one as well. Tech recommended replacing 4 systems due to age and cost of repair, approved of field supervisor getting in contact. Also units are flood units, field supervisor will be in contact shortly.
Replacement of condenser fan motor on system - 0707U03975 once replace system is operating properly at this time. Tech was informed another system condenser fan motor was spinning backwards. Tech found common side for 30 amp capacitor was burnt up and the od fan motor was jumped off that common as well tech replaced aced 30 amp capacitor with approval .tested the 50 mfd and the 7.5 mfd all within specs. Tech ran new common wire off the contactor to the 7.5mfd. System is operating properly at this time
Found the system operating with a high superheat of 33 and low subcool of 1.2. Delta T of only 10 degrees. Indoor and outdoor pistons. Temperature across Filter dryer is normal. Tech added 1lbs of R410a for testing purposes and decreased the airflow from speed tap #5(high static cooling) to #2(normal cooling). Evaporator coil is clean and return line appears to be good, filter is not clogged, all air vents have airflow, heat strips are not engaging. Tech managed to acquire a 14degree delta T after adjustments but bounces from 12 to 14 degrees. Reversing valve is switching over properly as well. 2nd option is required, pistons may not be sliding to properly meter. Office is aware of findings.
Tech found unit 2 circuit a was tripped alarm low superheat tech cleared code and monitored pressures circuit a 103/339 sh was 8 circuit b was 116/367 sh 26. Unit 1 circuit a is operating properly. Circuit b compressor sounds louder then normal pressure were 146/389. A few minutes later another company came with maintenance personnel and maintenance informed technician that they will keep in touch with Jacksonās and inform us on other company findings. Piedmont heating and air.
-Arrived to find outdoor unit not operating when called for at thermostat. Found air handler secondary float switch triggered in crawl space. Cleared drain line with compressed nitrogen, brushed condensate trap, and flushed line with algae tabs dissolved in water.
-System currently operating. Return temperature of 79 supply of 58. This temperature difference is slightly high. System may need follow up to further monitor refrigerant pressures with reasonable indoor temperature.
-System was recommended for UV lamp replacement. A working UV lamp will help to prevent algae buildup on coil and clogs in condensate drain.
-No service fee per maintenance plan.
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Tech found computer room mini split low on refrigerant and found evaporator coil leaking. Tech recommends replacing unit due to price of coil replacement. Tech also quoted pulling a vacuum and recharging factory charge.
Tech found mechanical room Mitsubishi thermostat blank. Tech replaced batteries and found thermostat lit up but would not respond to adjustments. Tech quoted thermostat replacement.
Tech found 4 floor 4 head mini split completely out of refrigerant. Tech found suction flare but has a large leak but also recommends searching all 4 heads. Tech quoted leak search, recharge and repair, but recommends looking into replacement as well due to price of repair. System holds 18 lbs plus 5 additional pounds for lineset length.
Tech pulled a vacuum and recharged computer room with factory charge per customer request. Unable to pull to 500 microns since system has a leak. Tech explained there is no guarantee on how long the recharge will last. Computer room is up and run
Updated proposal to replace upstairs system.
-Tenant stated system not cooling to satisfaction. Found thermostat set to 73 upon arrival. Found return temperature of 72 at air filter and 74 at outside duct hood. Found supply temperature of 58 at supply duct and 57 at outside duct hood. Air flow and air filter in good condition.
-Observed high pressure of 380, low pressure 139. Suspect restriction in refrigerant. Unplugged reversing valve in attempt to loosen piston metering device. Pressures dropped to 347 & 120 upon reconnecting.
-Found temperature difference of 5 degrees across filter drier. Suspect drier causing restriction. Recommend evacuate refrigerant, purge lines with nitrogen, replace filter drier, recharge system.
SANCTUARY- 5 TON DAIKIN CONDENSING UNIT & (2) COILS
Upon arrival tech found failed dual run capacitor, replaced capacitor after approval and tested system. Compressor and fan amp draws are within spec. System is back up and cooling. Customer invested in monthly service agreement. Customer stated they will have to update card info as current card is expiring this month.
Sold
Consultation Code: ENGDEV4YE
FOUND FAILED COMPRESSOR CAPACITOR. 17 YEAR OLD SYSTEM SHOWING OVERALL SIGNS OF WEAR. HEAVY RUST ON EVAPORATOR COILS. COMPRESSOR WINDINGS READING IN THE CAUTION RANGE. PLUG HAS OIL PRESENT, AND MELTED WIRING INDICATING FAILURE. HANDED OVER TO FIELD SUPERVISOR. REPLACED CAPACITOR TO GET SYSTEM RUNNING. PERFORMANCE NOT GUARANTEED.
FOUND COMPRESSOR OVERHEATED UPON ARRIVAL. COOLED COMPRESSOR AND FOUND IMPROPER RUNNING PRESSURES/LOW SUCTION. EVAPORATOR COIL LIGHTLY FROSTED. FOUND BLOWER SPEED SET LOW. ADJUSTED BLOWER SPEED TAP TO ACHIEVE PROPER PRESSURES. SYSTEM IS NOW OPERATING PROPERLY. WARRANTY.