Service tech very thorough and explained everything well.
Cheryl - Cary, NC 27518
Jesse J.
Tech preformed CMA FULL SERVICE on 7 split systems, 7 mini split systems, and 2 window units. Split system #4 is down due to compressor being shorted to ground. Recommend replacing system. Split system #5 is operating at this time, but compressor failed megohm test and evaporator coil has leak. Recommend replacing. Split system #1 is operating but has faulty thermostat, Recommend replacing thermostat. All mini splits systems are missing controls/ remotes, tech was able to activate mini split systems #2,#5,#6, and #7 with E.O. Switch on unit. All four systems are operating at this time. Mini split system #1 and #3 would not activate with E.O. Switch. Mini split #4 has error causing condenser unit not to activate. Recommend demand tech for further diagnosis of mini split systems #1, #3, and #4. Tech also recommends controls or remotes be installed for all mini split systems. Both window units run but do not cool. Recommend replacing. Tech has attached estimates to invoice for any minor r
Matt C.
Tech returned to drop off filters
Matt C.
Tech washed and serviced unit Customer extended 2 system psa, tech replaced weak dual run capacitor with turbo capacitor after customer approval
Kyle W.
TRANE SYMBIO SYSTEM ONLY RECEIVING PARTIAL POWER FROM MAIN PANEL. ELECTRICIAN WILL BE NEEDED TO FURTHER DIAGNOSE. SPOKE WITH MRS. DIVYA.
Kevin B.
Install Carrier 12.5-Ton Gas Pack
Donald S.
System ending in 919D has a bad tensioner and belt. Recommend a bx62 rubber belt with the tensioner. The heat does not work, the limit switch is burnt the hot surface ignitor is broken. The gas is not turned on so don’t even know if unit will fire up Heat exchanger exhaust is very rusty and inducer does not move a lot of air through heat exchanger. Heat exchanger has a hole in it. Because the heat needs extensive repairs recommended new system. Curbing unit sits on is also damaged
David C.
TECHNICIANS REMOVED THE OLD UNIT AND REPLACED IT WITH A NEW TRANE 7.5 TON SPLIT HEAT PUMP
Joshua W.
Tech is servicing a Trane split system.
Randy K.
Inspect Carrier furnace and AC, changed filter
Randy K.
Full service on a Trane heat pump, changed filter.
Jospeh A.
Performed inspection on trane system.