Jackson and Sons has provided full-service residential and commercial heating and air conditioning installation, maintenance tune-ups and repair services in Beulaville, NC since 1974.
Read our reviews to learn why your neighbors call us first for their home and business comfort needs in Beulaville, NC, then call us at 919-734-9611 to see what we can do for you.
Recent Jobs and Reviews in Beulaville, NC
Our Local Reviews by City
- 1, NC (1)
- 7, Beaver Creek, NC (1)
- 9, NC (2)
- Albertson, NC (13)
- Angier, NC (20)
- Atlantic Beach, NC (2)
- Ayden, NC (18)
- Bailey, NC (5)
- Bayboro, NC (3)
- Beaufort, NC (1)
- Benson, NC (10)
- Bentonville, NC (1)
- Bethel, NC (2)
- Beulah, NC (1)
- Beulaville, NC (17)
- Black Creek, NC (1)
- Boon Hill, NC (3)
- Brogden, NC (158)
- Buck Swamp, NC (29)
- Bull Head, NC (1)
- Calypso, NC (5)
- Cary, NC (1)
- Chinquapin, NC (1)
- Clayton, NC (135)
- Cleveland, NC (2)
- Clinton, NC (63)
- Contentnea Neck, NC (1)
- Cove City, NC (3)
- Deep Run, NC (27)
- Dover, NC (2)
- Dudley, NC (95)
- Dunn, NC (8)
- Elizabethtown, NC (1)
- Emerald Isle, NC (19)
- Ernul, NC (3)
- Eureka, NC (1)
- Fairfield Harbour, NC (5)
- Faison, NC (34)
- Falling Creek, NC (5)
- Farmville, NC (20)
- Fork, NC (25)
- Four Oaks, NC (58)
- Fremont, NC (118)
- Fuquay-Varina, NC (3)
- Garner, NC (14)
- Godwin, NC (2)
- Goldsboro, NC (3743)
- Grantham, NC (2)
- Great Swamp, NC (1)
- Greenville, NC (120)
- Grifton, NC (10)
- Grimesland, NC (1)
- Havelock, NC (9)
- Hookerton, NC (13)
- Hubert, NC (1)
- Indian Springs, NC (49)
- Institute, NC (5)
- Jacksonville, NC (7)
- Jason, NC (1)
- Kenansville, NC (11)
- Kenly, NC (68)
- Kinston, NC (182)
- Knightdale, NC (10)
- La Grange, NC (258)
- Lillington, NC (3)
- Limestone, NC (1)
- Lucama, NC (4)
- Macclesfield, NC (5)
- Magnolia, NC (2)
- Mar-Mac, NC (15)
- Micro, NC (2)
- Middlesex, NC (2)
- Morehead, NC (2)
- Morehead City, NC (9)
- Moseley Hall, NC (6)
- Mount Olive, NC (177)
- Nashville, NC (12)
- Neuse, NC (1)
- Neuse Forest, NC (1)
- New Bern, NC (141)
- New Hope, NC (38)
- Newton Grove, NC (32)
- North Clinton, NC (1)
- O'Neals, NC (1)
- Oriental, NC (1)
- Pikeville, NC (353)
- Pine Level, NC (5)
- Piney Green, NC (1)
- Piney Grove, NC (2)
- Pink Hill, NC (16)
- Plain View, NC (1)
- Pleasant Grove, NC (3)
- Princeton, NC (140)
- Raleigh, NC (2)
- River Bend, NC (3)
- Rocky Mount, NC (37)
- Rose Hill, NC (1)
- Roseboro, NC (6)
- Salter Path, NC (1)
- Saulston, NC (21)
- Selma, NC (74)
- Seven Springs, NC (91)
- Shine, NC (3)
- Sims, NC (2)
- Smithfield, NC (132)
- Sneads Ferry, NC (2)
- Snow Hill, NC (99)
- Southwest, NC (1)
- Stantonsburg, NC (20)
- Stoney Creek Township, NC (35)
- Swansboro, NC (4)
- Tarboro, NC (6)
- Trent Woods, NC (11)
- Trenton, NC (4)
- Turkey, NC (5)
- Vanceboro, NC (6)
- Wake Forest, NC (1)
- Wallace, NC (4)
- Walnut Creek, NC (45)
- Walstonburg, NC (5)
- Warsaw, NC (29)
- Wendell, NC (10)
- WESLEYAN COL, NC (1)
- Wilders, NC (3)
- Willow Spring, NC (1)
- Wilmington, NC (1)
- Wilson, NC (41)
- Wilson Mills, NC (1)
- Winterville, NC (64)
- Zebulon, NC (3)
Job Locations and Reviews
Landen H.
Tech washed and serviced unit and found no challenges at this time. Customer was home when tech arrived to give access to inside portion and also extended PSA via Visa card customer had to leave for work soon as tech started tech was able to get in and check thermostat and delta t unit is cooling with a delta t of 20 return of 72 and a supply of 52
Beulaville, NC 28518
Landen H.
Tech returned to wash unit and clean coils customer was not interested in extending plan today due to financial difficulties.
Beulaville, NC 28518
Joseph C.
Tech performed ESA on 1 system. Split system- tech found system had no float switches tech recommended installation float switch on pan, no further challenges at today’s visit. Recommendation- installing float switch to pan to prevent overflow, customer stated they are interested but unable to do at this time.
Beulaville, NC 28518
Joseph C.
Tech arrived to perform energy saving agreement. Tech found water spigot on opposite side of house, tech doesn’t have enough hose to reach system. Tried to call customer to see if they had any hoses but all hoses had holes. Will need to come back 3 water hoses to wash coils and system. Tech inspected all electrical and cleaned evaporator coil, tech spoke with customer he is going to take care of renewal when we come back.
Beulaville, NC 28518
Bryce C.
Brother met me at home. Emailed proposal
Beulaville, NC 28518
Nate R.
Dog was not put up, Office will call to reschedule.
Beulaville, NC 28518
Nate R.
Tech serviced and washed unit. Found no challenges at this time, customer stated they did not want to renew because they won’t be in this house much longer.
Beulaville, NC 28518
Matthew L.
Customer did not understand why indoor unit kept running even when outdoor breaker was off. Tech explained that air handler in attic is on a separate circuit from outdoor unit and will continue to run the blower even if outdoor unit is off. Tech found blower control board EZ select on factory default jumper settings. Tech peeled sticker on board to reveal jumper setting labels. Corrected jumper settings for 2 ton split heat pump with 2 stage compressor, 10kw single stage heater (jumped together at factory W2 jumper), comfort, enhanced, and nominal airflow settings. Turned system on and off in each mode after correcting blower control board. Found no further issues with system after correcting blower board jumpers. Connected new Vision Pro to Wi-Fi network and turned scheduling off per customer preference. Customer does not have his email and password to Honeywell account. To connect new Vision Pro to customer’s existing Honeywell account, customer’s daughter will need to find or rec
Beulaville, NC 28518
Brett S.
Tech performed maintenance per service agreement. Tech found upstairs air handler receiving no power. Tech noticed Generac was not receiving power, causing air handler to not receive power. This was noted by previous technician also. Homeowner is having an electrician come out today to check it out. Tech found blown UV bulb in package unit. Homeowner decided not to replace today. Tech replaced one 20 x 20 and two 16 x 20 filters. System is operating properly at this time.
Beulaville, NC 28518
Matthew L.
Customer reported PTAC unit in room above garage not cooling. Tech walked up to unit and saw it not running although control was set to cooling. Adjusted control and setpoint. Unit did not respond. Removed panel. A few seconds later, system started and ran in cooling by itself. Blower will not run at low speed. Blower shut off when set to low speed. Tested heat mode. Heat strips will run with blower off when set to low. Blower runs in high when set on high or auto. Compressor was still running in cooling mode with blower shut off while control is set to blower low setting. Blower does seem to run correctly when set to high or auto. 20 year old Fedders PTAC unit was manufactured in 2004 and uses R22. Tech diagnosed faulty PTAC control board not energizing low blower speed correctly. Due to age and likely cost of repair vs replacement, tech recommends replacing 20 year old PTAC unit. Need to call back with PTAC unit replacement quote. Wall sleeve exterior measurement is 16*42. See
Beulaville, NC 28518
Derek J.
Upon arrival homeowner stated there was not power on the thermostat. Tech inspected equipment and found there to be no line voltage feeding disconnect. Tech found Generac system breaks line voltage on equipment and believes Generac box caused the loss of power. Tech was able to get unit back up and running and told homeowner if it happened again to call the company the services generator system.
Beulaville, NC 28518
Wayne T.
25TPA724A003/FV4CNF003L00
Beulaville, NC 28518
Kyle W.
FOUND HEAT STRIP DISCONNECT FOR MAIN SYSTEM COMPLETELY METLED. CUSTOMER HAS ELECTRICIAN SCHEDULED TO FURTHER INSPECT/REPAIR. NOTICED COMPRESSOR FOR 2ND SYSTEM UNABLE TO START DURING TODAYS VISIT. CAPACITORS WITHIN SPECS. COMPRESSOR IS SEIZING UP AND CUTTING OUT ON THERMAL OVERLOAD. MEGHOHMS WITHIN BAD RANGE. HANDED OVER TO FIELD SUPERVISOR.
Beulaville, NC 28518
Ricardo T.
Tech washed and serviced unit and found no challenges at this time.
Beulaville, NC 28518
Matthew L.
Tech found no obvious issues with either HVAC outdoor unit. Tech found burnt hole where line voltage arc flashed through front cover of main electric meter to house. Tech let homeowner know. She is calling the power company. Tech let customer know there is no housecall on the Premium plan. Tech collected trip charge due to service call not being a HVAC unit issue.
Beulaville, NC 28518
Randy K.
Performed a filter change and maintenance inspection on a Trane heat pump, tested heat strips, capacitors, checked motor amps, T-stat, cleared drain trap.
Beulaville, NC 28518
Matthew L.
Tech found foam piece that sits between top panel of outdoor unit and outdoor coil brushing up against the fan blade. Tech removed top panel and secured foam to microchannel outdoor coil using push connectors. Replaced top panel and tested. No longer brushing fan blade. No charge per office.
Beulaville, NC 28518
Kyle W.
VERIFIED AIR HANDLER #5 IS NOT WIRED FOR HEAT STRIPS. OPERATING WELL WITHIN SPECS. BLOWING COLD AIR DURING DEFROST OPERATION DUE TO NO AUXILIARY HEAT. FOUND AIR HANDLER #2 DROPPING VOLTAGE TO THERMOSTAT DUE TO FAULTY PRIMARY FLOAT SWITCH. REPLACED FLOAT SWITCH. SYSTEM UP AND HEATING. UNIT #10 WATER COIL HEATING PROPERLY WITH A 22 DEGREE CHANGEOVER. MAINTENANCE STATED THEY HAVE A SYSTEM NEAR THAT IS DOWN AT THIS TIME. MAY BE CAUSING CHALLENGES WITH KEEPING TEMPERATURE DURING COLD SPELLS.
Beulaville, NC 28518
Nate R.
Tech dropped off 2 18x20x1 filters.
Beulaville, NC 28518
Matthew L.
4545* Unit 9 reported to be frozen up. Tech found defrost board and defrost sensor working correctly. After forcing defrost, suction and head pressure dropped into a vacuum. Tech diagnosed liquid line restriction due to shut down indoor TXV used for cooling mode and defrost. Tech left defrost thermostat unplugged so system will not attempt to defrost with a failed TXV. Heat strips are not wired up inside AHU 9. Tech checked system 5 and found it operating and defrosting correctly. Likely blowing cold air due to heat strips not being wired in as previously documented. Defrost will blow air conditioning and supply temperature will drop as outdoor temperature drops. Tech recommends a licensed electrician run the proper wire size to all the AHUs with unwired heat strips as previously documented. Need to quote indoor TXV for AHU #9. Maintenance man will manually defrost outdoor unit 9 for now. Tech billed for two diagnostics.
Beulaville, NC 28518
Joseph C.
Tech performed ESA on 1 system found no challenges customer stated condenser iced up tech tested defrost cycle and sensors with no challenges. Tech recommended getting on service agreement to keep system maintained customer invested in MPA. Need to drop off 18x20x1 filter
Beulaville, NC 28518
Review
Ricardo T.
Tech washed and serviced unit and found no challenges at this time.
Beulaville, NC 28518
Nate R.
Customer was not home tech washed and serviced unit and did everything he could outside found no challenges at this time.
Beulaville, NC 28518
Review
Landen H.
Performed routine maintenance per energy savings agreement, tech found no challenges at the time of service. System is heating properly and holding a delta t of 20+ degrees. Customer renewed PSA via card
Beulaville, NC 28518
Nate R.
Tech washed and serviced outside portion of service tech got no answer at the door contact us when you would like the inside portion done. Tech found no challenges at this time.
Beulaville, NC 28518